view docs/html/sdlsettimer.html @ 1558:b46bb79cc197

Fixed bug #113: Date: Sat, 16 Apr 2005 08:39:22 +1000 From: "Eric Mangold" Subject: [SDL] Window manager does not show SDL window titles Hello, I have an issue with SDL-using applications and the sawfish window manager. The problem is that SDL windows do not show the window caption. My gnome panel *does* show the window name, but the actual sawfish window frame shows no caption at all. All other non-SDL applications that I use work fine. I tried a couple other window managers, and they *were* able to show the SDL window captions correctly. Though there many be other WMs that can't. I believe the problem is that SDL is using the UTF8_STRING type for the window's WM_NAME and WM_ICON properties. In fact, WM_NAME and WM_ICON are supposed to set to a TEXT type, usually STRING (ISO 8859-1). The property names _NET_WM_NAME and _NET_WM_ICON_NAME should be used to store the UTF8_STRING versions of the window title and icon name. You can see the properties I refer to with a command like this: xprop|grep -e "WM.*NAME" Please note the freedesktop.org standard: http://standards.freedesktop.org/wm-spec/wm-spec-1.3.html#id2506954 This page talks a little bit about the history of these properties. Just search down the page for "WM_NAME". http://www.cl.cam.ac.uk/~mgk25/unicode.html Please let me know if I can be of any assistance in resolving this issue. Thanks, Eric Mangold
author Sam Lantinga <slouken@libsdl.org>
date Mon, 20 Mar 2006 07:31:36 +0000
parents 355632dca928
children
line wrap: on
line source

<HTML
><HEAD
><TITLE
>SDL_SetTimer</TITLE
><META
NAME="GENERATOR"
CONTENT="Modular DocBook HTML Stylesheet Version 1.76b+
"><LINK
REL="HOME"
TITLE="SDL Library Documentation"
HREF="index.html"><LINK
REL="UP"
TITLE="Time"
HREF="time.html"><LINK
REL="PREVIOUS"
TITLE="SDL_RemoveTimer"
HREF="sdlremovetimer.html"></HEAD
><BODY
CLASS="REFENTRY"
BGCOLOR="#FFF8DC"
TEXT="#000000"
LINK="#0000ee"
VLINK="#551a8b"
ALINK="#ff0000"
><DIV
CLASS="NAVHEADER"
><TABLE
SUMMARY="Header navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TH
COLSPAN="3"
ALIGN="center"
>SDL Library Documentation</TH
></TR
><TR
><TD
WIDTH="10%"
ALIGN="left"
VALIGN="bottom"
><A
HREF="sdlremovetimer.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="80%"
ALIGN="center"
VALIGN="bottom"
></TD
><TD
WIDTH="10%"
ALIGN="right"
VALIGN="bottom"
>&nbsp;</TD
></TR
></TABLE
><HR
ALIGN="LEFT"
WIDTH="100%"></DIV
><H1
><A
NAME="SDLSETTIMER"
></A
>SDL_SetTimer</H1
><DIV
CLASS="REFNAMEDIV"
><A
NAME="AEN8557"
></A
><H2
>Name</H2
>SDL_SetTimer&nbsp;--&nbsp;Set a callback to run after the specified number of milliseconds has
elapsed.</DIV
><DIV
CLASS="REFSYNOPSISDIV"
><A
NAME="AEN8560"
></A
><H2
>Synopsis</H2
><DIV
CLASS="FUNCSYNOPSIS"
><A
NAME="AEN8561"
></A
><P
></P
><PRE
CLASS="FUNCSYNOPSISINFO"
>#include "SDL.h"</PRE
><P
><CODE
><CODE
CLASS="FUNCDEF"
>int <B
CLASS="FSFUNC"
>SDL_SetTimer</B
></CODE
>(Uint32 interval, SDL_TimerCallback callback);</CODE
></P
><P
></P
></DIV
></DIV
><DIV
CLASS="REFSECT1"
><A
NAME="SDLTIMERCALLBACK"
></A
><H2
>Callback</H2
><P
>/* Function prototype for the timer callback function */
typedef Uint32 (*SDL_TimerCallback)(Uint32 interval);</P
></DIV
><DIV
CLASS="REFSECT1"
><A
NAME="AEN8570"
></A
><H2
>Description</H2
><P
>Set a callback to run after the specified number of milliseconds has
elapsed. The callback function is passed the current timer interval
and returns the next timer interval.  If the returned value is the
same as the one passed in, the periodic alarm continues, otherwise a
new alarm is scheduled.</P
><P
>To cancel a currently running timer, call
<TT
CLASS="FUNCTION"
>SDL_SetTimer(0, NULL);</TT
></P
><P
>The timer callback function may run in a different thread than your
main constant, and so shouldn't call any functions from within itself.</P
><P
>The maximum resolution of this timer is 10 ms, which means that if
you request a 16 ms timer, your callback will run approximately 20 ms
later on an unloaded system.  If you wanted to set a flag signaling
a frame update at 30 frames per second (every 33 ms), you might set a
timer for 30 ms (see example below).</P
><P
>If you use this function, you need to pass <TT
CLASS="LITERAL"
>SDL_INIT_TIMER</TT
>
to <TT
CLASS="FUNCTION"
>SDL_Init()</TT
>.</P
><DIV
CLASS="NOTE"
><BLOCKQUOTE
CLASS="NOTE"
><P
><B
>Note: </B
>This function is kept for compatibility but has been superseded
by the new timer functions
<A
HREF="sdladdtimer.html"
>SDL_AddTimer</A
> and
<A
HREF="sdlremovetimer.html"
>SDL_RemoveTimer</A
> which support
multiple timers.</P
></BLOCKQUOTE
></DIV
></DIV
><DIV
CLASS="REFSECT1"
><A
NAME="AEN8584"
></A
><H2
>Examples</H2
><P
><PRE
CLASS="PROGRAMLISTING"
>SDL_SetTimer((33/10)*10, my_callback);</PRE
></P
></DIV
><DIV
CLASS="REFSECT1"
><A
NAME="AEN8588"
></A
><H2
>See Also</H2
><P
><A
HREF="sdladdtimer.html"
><TT
CLASS="FUNCTION"
>SDL_AddTimer</TT
></A
></P
></DIV
><DIV
CLASS="NAVFOOTER"
><HR
ALIGN="LEFT"
WIDTH="100%"><TABLE
SUMMARY="Footer navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
><A
HREF="sdlremovetimer.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="index.html"
ACCESSKEY="H"
>Home</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
>&nbsp;</TD
></TR
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
>SDL_RemoveTimer</TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="time.html"
ACCESSKEY="U"
>Up</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
>&nbsp;</TD
></TR
></TABLE
></DIV
></BODY
></HTML
>