view docs/html/sdlquitsubsystem.html @ 2318:0c653886cce7

HandleEvent() returns done each time it is called. If done was set to 0 the program should quit, but because done is not checked until *all* events are handled a following event can reset done to 1 and prevent the program from terminating when told to. I fixed the while loop that handles events to check for the state of done after handling each event. That could leave some events unhandled when the program exits, but it ensures that the program will exit.
author Bob Pendleton <bob@pendleton.com>
date Wed, 20 Feb 2008 23:27:33 +0000
parents 355632dca928
children
line wrap: on
line source

<HTML
><HEAD
><TITLE
>SDL_QuitSubSystem</TITLE
><META
NAME="GENERATOR"
CONTENT="Modular DocBook HTML Stylesheet Version 1.76b+
"><LINK
REL="HOME"
TITLE="SDL Library Documentation"
HREF="index.html"><LINK
REL="UP"
TITLE="General"
HREF="general.html"><LINK
REL="PREVIOUS"
TITLE="SDL_InitSubSystem"
HREF="sdlinitsubsystem.html"><LINK
REL="NEXT"
TITLE="SDL_Quit"
HREF="sdlquit.html"></HEAD
><BODY
CLASS="REFENTRY"
BGCOLOR="#FFF8DC"
TEXT="#000000"
LINK="#0000ee"
VLINK="#551a8b"
ALINK="#ff0000"
><DIV
CLASS="NAVHEADER"
><TABLE
SUMMARY="Header navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TH
COLSPAN="3"
ALIGN="center"
>SDL Library Documentation</TH
></TR
><TR
><TD
WIDTH="10%"
ALIGN="left"
VALIGN="bottom"
><A
HREF="sdlinitsubsystem.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="80%"
ALIGN="center"
VALIGN="bottom"
></TD
><TD
WIDTH="10%"
ALIGN="right"
VALIGN="bottom"
><A
HREF="sdlquit.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
></TABLE
><HR
ALIGN="LEFT"
WIDTH="100%"></DIV
><H1
><A
NAME="SDLQUITSUBSYSTEM"
></A
>SDL_QuitSubSystem</H1
><DIV
CLASS="REFNAMEDIV"
><A
NAME="AEN550"
></A
><H2
>Name</H2
>SDL_QuitSubSystem&nbsp;--&nbsp;Shut down a subsystem</DIV
><DIV
CLASS="REFSYNOPSISDIV"
><A
NAME="AEN553"
></A
><H2
>Synopsis</H2
><DIV
CLASS="FUNCSYNOPSIS"
><A
NAME="AEN554"
></A
><P
></P
><PRE
CLASS="FUNCSYNOPSISINFO"
>#include "SDL.h"</PRE
><P
><CODE
><CODE
CLASS="FUNCDEF"
>void <B
CLASS="FSFUNC"
>SDL_QuitSubSystem</B
></CODE
>(Uint32 flags);</CODE
></P
><P
></P
></DIV
></DIV
><DIV
CLASS="REFSECT1"
><A
NAME="AEN560"
></A
><H2
>Description</H2
><P
><TT
CLASS="FUNCTION"
>SDL_QuitSubSystem</TT
> allows you to shut down a subsystem that has been previously initialized by <A
HREF="sdlinit.html"
><TT
CLASS="FUNCTION"
>SDL_Init</TT
></A
> or <A
HREF="sdlinitsubsystem.html"
><TT
CLASS="FUNCTION"
>SDL_InitSubSystem</TT
></A
>. The <TT
CLASS="PARAMETER"
><I
>flags</I
></TT
> tells <TT
CLASS="FUNCTION"
>SDL_QuitSubSystem</TT
> which subsystems to shut down, it uses the same values that are passed to <A
HREF="sdlinit.html"
><TT
CLASS="FUNCTION"
>SDL_Init</TT
></A
>.</P
></DIV
><DIV
CLASS="REFSECT1"
><A
NAME="AEN572"
></A
><H2
>See Also</H2
><P
><A
HREF="sdlquit.html"
><TT
CLASS="FUNCTION"
>SDL_Quit</TT
></A
>,
<A
HREF="sdlinit.html"
><TT
CLASS="FUNCTION"
>SDL_Init</TT
></A
>,
<A
HREF="sdlinitsubsystem.html"
><TT
CLASS="FUNCTION"
>SDL_InitSubSystem</TT
></A
></P
></DIV
><DIV
CLASS="NAVFOOTER"
><HR
ALIGN="LEFT"
WIDTH="100%"><TABLE
SUMMARY="Footer navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
><A
HREF="sdlinitsubsystem.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="index.html"
ACCESSKEY="H"
>Home</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
><A
HREF="sdlquit.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
>SDL_InitSubSystem</TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="general.html"
ACCESSKEY="U"
>Up</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
>SDL_Quit</TD
></TR
></TABLE
></DIV
></BODY
></HTML
>